A novel bioelectrochemical BOD sensor operating with voltage input
By Modin, Oskar & Wilén, Britt-Marie
Published in Water Research
NULL
2012
Abstract
Biochemical oxygen demand (BOD) is a measure of biodegradable compounds in water and is, for example, a common parameter to design and assess the performance of wastewater treatment plants. The conventional method to measure BOD is time consuming (5 or 7 days) and requires trained personnel. Bioelectrochemical BOD sensors designed as microbial fuel cells (MFCs), which are systems where bacteria convert organic matter into an electrical current, have emerged as an alternative to the conventional technique. In this study, a new type of bioelectrochemical BOD sensor with features that overcome some of the limitations of current MFC-type designs was developed: (1) An external voltage was applied to overcome internal resistances and allow bacteria to generate current at their full capacity, and (2) the ion exchange membrane was omitted to avoid pH shifts that would otherwise limit the applicability of the sensor for wastewaters with low alkalinity. The sensor was calibrated with an aerated nutrient medium containing acetate as the BOD source. Linear correlation (R2Â =Â 0.97) with charge was obtained for BOD concentrations ranging from 32 to 1280Â mg/L in a reaction time of 20Â h. Lowering the reaction time to 5Â h resulted in lowering the measurable BOD concentration range to 320Â mg/L (R2Â =Â 0.99). Propionate, glucose, and ethanol could also be analyzed by the sensor that was acclimated to acetate. The study demonstrates a way to design more robust and simple bioelectrochemical BOD sensors that do not suffer from the usual limitations of MFCs (high internal resistance and pH shifts).
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.