Interface 5000E
The Interface 5000E is an electrochemical test system designed for single-cell battery testing or any other energy device. It can perform a series of electrochemical tests such as voltage and impedance of two half cells and full cells.
double potentiometer
The dual potentiometer design enables simultaneous electrochemical measurements of two half-cells in a typical three-electrode system design. In charge-discharge and impedance measurements, simultaneous electrochemical characterization of the entire cell, as well as anode and cathode, can be achieved.

(Click image to Enlarge)Published EIS accuracy, not claimed accuracy
Accuracy Contour Plot
The accuracy contour plot provides a detailed look at the performance you can expect from your instrument in real-world situations. The results include the cell cable. Accuracy contour plots are important because they let you compare the performance of different manufacturers to ensure you are getting the best possible measurement.
Multichannel Potentiostat
The Interface 5030 can be configured as a single-channel potentiostat, bipotentiostat, or multichannel-potentiostat providing you with the flexibility you need to get more done.

Below are more features about the Interface 5000E Electrochemical Workstation.
-
Electrochemical energy - test single cell or stack, fuel cell or super capacitor charge, discharge, cycle charge and discharge, constant potential, constant current, self-discharge, leakage current, read battery voltage, etc.
-
Electrochemical Impedance Spectroscopy - including potentiostatic, galvanostatic and hybrid impedance spectroscopy experiments with Mott-Schottky experimental techniques at single point frequencies. Adopt unique power leveling multisine technology to improve signal-to-noise ratio. In terms of analysis, there are equivalent circuit model analysis data software, Kramers-Kronig transform data verification data reliability and impedance graphical model editor. .
-
Physical Electrochemistry - Cyclic Voltammetry, Chronoamperometry, and Chronopotentiometry and related techniques derived from these measurements.
-
Pulse Voltammetry - Pulse voltammetry, square wave voltammetry, and related techniques such as anodic stripping voltammetry.
-
DC Corrosion - Run standard DC corrosion tests such as polarization resistance, potential, cyclic polarization and galvanic corrosion, etc.
-
Electrochemical Signal Analyzer - Software for acquisition and analysis of time-correlated electrochemical noise signals. Continuous monitoring of voltage and current at rates from 0.1 Hz to 1 kHz. Full-featured analysis tools such as statistical analysis, trend, impedance spectroscopy, and histogram analysis.
-
Electrochemical Frequency Modulation - A Nondestructive Corrosion Rate Measurement Method. With this technique, the corrosion rate is directly measured without Tafel's constant. In addition, the technique can determine the Tafel constant and provide parameters related to pitting.
-
Critical Pitting Temperature - Controls the Gamry potentiostat, TDC4 temperature controller, and related accessories to automatically measure the critical pitting temperature of materials.
-
Electrochemical Noise - Electrochemical noise testing is a more general technique. It is compatible with the ECM8 multiplexer software package for electrochemical noise measurements.
-
eChemAC Toolkit - Software toolkit for full control of potentiostats for impedance (EIS) measurements and EFM experiments.
other details
Interface 5030E Part #992-00244 / #992-244