Interface 1030B

The Interface 1030B TM  is an introductory electrochemical instrument with capabilities for all electrochemical techniques — physical and analytical electrochemistry, pulse voltammetry and DC corrosion, with EIS to 20 kHz across nine current ranges to ±1 A and ±12V.

 

What it does

 

  • Nine current ranges from 10 nA to 1 A, eleven with internal gain
  • Built-in EIS to 20 kHz
  • Potentiostat, galvanostat, and ZRA modes without added hardware
  • Same hardware as the 1030E with limits set in software — upgradeable to a 1030E
  • Floating instrument for autoclaves and pipeline probes

 

系统特点:

Interface 1010B

Designed for cyclic voltammetry or similar fundamental research, such as determining redox potentials, reaction mechanisms, diffusion coefficients, rate constants, and electrochemical active areas. It can also run electroplating and electroplating experiments or determine the concentration of trace analytes in solution. In addition to these functions, an introductory software development kit is included, allowing for the development of custom programs or interface capabilities with other instruments.

The Interface 1010B can also be expanded into more advanced models. The Interface 1010E provides all the functionality of the Interface 1010B and also includes electrochemical impedance spectroscopy (EIS) capabilities.

The Interface 1010B can be upgraded to a more advanced electrochemical testing system. Contact GAMRY for more information on upgrading the Interface 1010B to the 1010E.

更多细节

The following describes the features of the Interface 1010B electrochemical workstation.

  • Physical electrochemistry - cyclic voltammetry, linear sweep voltammetry, chronoamperometry, chronopotentialometry, chronocoulometric voltammetry, multi-step chronoamperometry, and multi-step chronopotentialometry.
  • Pulse voltammetry – Differential pulse voltammetry, conventional pulse voltammetry, reverse pulse voltammetry, Osteryoung square wave voltammetry, and related techniques such as anodic stripping voltammetry.
  • Applications of basic control and user-defined signals. Simple constant potential and constant current experiments can be performed. Define arrays to perform linear scans and cyclic voltammetry.

Other details

  • Measurements of electrodes 2, 3, 4, and 5
  • Electrically isolated floating ground: used in autoclaves, mechanical stress equipment or pipelines.
  • DSP (Digital Signal Processing) mode
  • Oversampling mode improves signal-to-noise ratio and accurate capacitance measurement.
  • Current interruption IR compensation
  • Input, analog voltage output, analog current output, auxiliary
  • A/D inputs and digital I/O connectors.
  • Value retention period
  • Two-year manufacturer's warranty service.

 

下栽

Interface 1010B Part #992-00116

参数与

system

Potentiostat yes
Constant current meter yes
Zero-resistance current meter yes
Floating ground design (insulated from the ground) yes
Electrode connection 2, 3 or 4 electrodes
High current ±1 A
Current range 9 (10 nµA-1A)
Current range (including internal gain) 11
Small current resolution 3.3 fA
Large applied potential ±11V
Ascent Time <1 μs
Small time base  10 μs
Noise and ripple (typical) <20 μV rms
weight 2.4 kg
2.4 kg 24 (W) x 6 (H) x 27 (D) 27 cm
   

Control amplifier

slot pressure ±20 V (@ 1A)
Output Current >±1 A
Speed ​​setting 5
Gain bandwidth (typical) 980, 260, 40, 4, 0.4 kHz
   

potentiometer

Input impedance >10 12 Ω
Input current <20 pA
bandwidth >10 MHz
Common-mode rejection ratio >80 dB (10 kHz)
>60 dB (1 MHz)
   

Potential

Application accuracy    ±1 mV ±0.2% Setting range
Apply resolution 200 μV, 50 μV, 12.5 μV/bit
Measurement accuracy ±1 mV ±0.3% Reading range
Measurement resolution 1 μV, 10 μV, 100 μV, 400 μV/bit
   

Apply current

Application accuracy    ±5 pA ±0.3% range
Apply resolution 0.0033%
   

Measuring current

Measurement accuracy ±5 pA ±0.3% Application/Measurement Resolution
Measurement resolution 0.0033%
Apply/Measure Resolution >10 MHz (1A - 100 μA)
>1.5 MHz (10 μA)
>0.15 MHz (1 μA)