Dependence on Temperature, pH, and Cl? in the Uniform Corrosion of Aluminum Alloys 2024-T3, 6061-T6, and 7075-T6
By I-Wen Huang and Belinda L. Hurley and Fan Yang and Rudolph G. Buchheit
Published in Electrochimica Acta
NULL
2016
Abstract
With regards to localized corrosion, the role of uniform corrosion of aluminum alloys has not always been accounted for in the past. The impact of uniform corrosion on aluminum alloys 2024-T3, 6061-T6, and 7075-T6 is studied here to provide quantitative evidence of its importance. Preliminary weight loss experiments combined with optical profilometry (OP) indicate that corrosion attributed to uniform corrosion is very significant when compared to localized corrosion. A series of free immersion tests were conducted to understand the influence of environmental variables including temperature (20, 40, 60, 80
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.