Electrochemical characteristics of high-Pd alloys in relation to Pd-allergy
By Berzins, D.W.; Kawashima, I.; Graves, R. & Sarkar, N.K.
Published in Dental Materials
NULL
2000
Abstract
Objective: The aim of this study was to determine whether the Pd–Cu-based dental ceramic alloys possess any electrochemical characteristics distinguishable from that of other Pd-containing alloys. Of all Pd-containing alloys, this particular alloy group has been linked to frequent incidence of allergy and hypersensitivity reactions. Electrochemical corrosion may instigate these reactions. Methods: Four groups of alloys, Pd–Cu, Pd–Ga-(with and without Ag), Pd–Ag, and Au–Pd, were evaluated by traditional corrosion measurement techniques in a phosphated buffer saline solution at 20°C. The electrochemical characteristics measured were: (1) 20 h open circuit potential (OCP); (2) 20 h corrosion rate (Icorr); and (3) anodic polarization (E–i) curves. Results: The OCP values (232±25 mV) of the Ag-free Pd–Ga and Pd–Cu-based alloys were higher than and distinctly different from that (144±52 mV) of the Ag-containing alloys. The Icorr values of different alloys, despite varied compositions, were indistinguishable from one another. The E–i curves of all alloys were essentially similar, with the Ag-containing (>5 wt%) alloys showing a subtle difference in their anodic slope within 100 mV above their corrosion potentials. Significance: The OCP values of Pd–Cu alloys and the Ag-free Pd–Ga alloy are comparable to that reported for pure Pd (239±21 mV), which indicates that during corrosion these alloys undergo dealloying and consequent Pd-enrichment on their surface. Such a condition is conducive to the release of allergenic Pd++ ions and offers a plausible explanation for the frequent incidence of hypersensitivity reactions associated with the Pd–Cu alloys. The OCP values in other alloys are attributed to dealloying followed by surface enrichment with Ag and/or Au and the possible formation of an insoluble AgCl surface film on the respective alloy surfaces. These events have the potential to suppress or prevent Pd++ ion release. Alloys showing these characteristics have seldom been linked to allergic reactions.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.