Reverse Current Pulse Method To Restore Uniform Concentration Profiles in Ion-Selective Membranes. 1. Galvanostatic Pulse Methods with Decreased Cycle Time
By Zook, Justin M. & Lindner, Ernš‘
Published in Analytical Chemistry
NULL
2009
Abstract
The applications of ion-selective electrodes (ISEs) have been broadened through the introduction of galvanostatic current pulse methods in potentiometric analysis. An important requirement in these applications is the restoration of the uniform equilibrium concentration profiles in the ISE membrane between each measurement. The simplest restoration method is zero-current relaxation, in which the membrane relaxes under open-circuit conditions in a diffusion-controlled process. This paper presents a novel restoration method using a reverse current pulse. An analytic model for this restoration method is derived to predict the concentration profiles inside ISE membranes following galvanostatic current pulses. This model allows the calculation of the voltage transients as the membrane voltage relaxes back toward its zero-current equilibrium value. The predicted concentration profiles and voltage transients are confirmed using spectroelectrochemical microscopy (SpECM). The reverse current restoration method described in this paper reduces the voltage drift and voltage error by 10-100 times compared to the zero-current restoration method. Therefore, this new method provides faster and more reproducible voltage measurements in most chronopotentiometric ISE applications, such as improving the detection limit and determining concentrations and diffusion coefficients of membrane species. One limitation of the reverse current restoration method is that it cannot be used in a few applications that require background electrolyte loaded membranes without excess of lipophilic cation exchanger.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.