Multi-material Ti6Al4V & PEEK cellular structures produced by Selective Laser Melting and Hot Pressing: A tribocorrosion study targeting orthopedic applications
By Bartolomeu, F.; Buciumeanu, M.; Costa, M. M.; Alves, N.; Gasik, M.; Silva, F. S.; Miranda, G.
Published in Journal of the Mechanical Behavior of Biomedical Materials
2019
Abstract
Ti6Al4V-alloy is commonly used in dental and orthopedic applications where tribochemical reactions occur at material/bone interface. These reactions are one of the main concerns regarding Ti6Al4V implants due to the generation of wear particles, linked to the release of metallic ions in toxic concentration which occurs when TiO2 passive film is destroyed by means of wear and corrosion simultaneously. In the present study, a multi-material Ti6Al4V-PEEK cellular structure is proposed. Selective Laser Melting technique was used to produce Ti6Al4V dense and cellular structured specimens, whilst Hot-Pressing technique was employed to obtain multi-material Ti6Al4V-PEEK structures. This study investigates the tribocorrosion behavior of these materials under reciprocating sliding, comparing them with commercial forged Ti6Al4V. Open-circuit-potential was measured before, during and after sliding while dynamic coefficient of friction was assessed during sliding. The results showed an improved wear resistance and a lower tendency to corrosion for the multi-material Ti6Al4V-PEEK specimens when compared to dense and cellular structures mono-material specimens. This multi-material solution gathering Ti6Al4V and PEEK, besides being able to withstand the loads occurring after implantation on dental and orthopedic applications, is a promising alternative to fully dense metals once it enhances the tribocorrosion performance.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.