Corrosion behavior of shape memory, superelastic, and nonsuperelastic nickel–titanium-based orthodontic wires at various temperatures
By Pun, Deo K. & Berzins, David W.
Published in Dental Materials
NULL
2008
Abstract
Objective Nickel–titanium orthodontic wires have various temperature-dependent phases. The purpose of this study was to investigate temperature-dependent corrosion characteristics of shape memory, superelastic, and nonsuperelastic orthodontic wires. Methods Four orthodontic wires were investigated: 27 and 40 °C copper Ni–Ti (superelastic and shape memory, respectively), superelastic Ni–Ti, and nonsuperelastic Nitinol Classic. Differential scanning calorimetry (DSC) was used to confirm phase/temperature behavior of the wires. Sectioned halves of as-received archwires were assessed electrochemically in artificial saliva at 5, 24, 37, and 45 °C. Open circuit potential (OCP) was monitored for 2 h followed by polarization resistance and cyclic polarization tests. Results DSC results showed Nitinol was primarily martensitic-stable whereas NiTi, 27 °C CuNiTi, and 40 °C CuNiTi possessed austenite-finish temperatures of approximately 19, 21, and 38 °C. The OCP of the CuNiTi wires was significantly greater than NiTi and Nitinol but no apparent trend in values was apparent with regard to temperature or phases present. Corrosion current density (icorr) increased with temperature for all wires, but not all were equally influenced. The two lowest austenite-finish temperature wires (27 °C CuNiTi and NiTi) approximately tripled in icorr from 37 to 45 °C. Greater incidence of pitting was observed in the CuNiTi wires. Significance This study showed the corrosion rate of various nickel–titanium wires increase with temperature and different phases present may influence corrosion rate trends.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.