Synthesis and Characterization of Poly(vinylidene fluoride)-g-sulfonated Polystyrene Graft Copolymers for Proton Exchange Membrane
By Zhang, Zhicheng; Chalkova, Elena; Fedkin, Mark; Wang, Chunmei; Lvov, Serguei N.; Komarneni, Sridhar & Chung, T. C. Mike
Published in Macromolecules
NULL
2008
Abstract
A series of poly(vinylidene fluoride)-g-sulfonated polystyrene (PVDF-g-SPS) graft copolymers were systematically synthesized and examined with the focus of understanding how the polymer microstructure (backbone molecular weight, graft density, graft length, sulfonic acid concentration, ion exchange capacity, etc.) affects their morphology, water uptake, and proton conductivity under various environmental conditions (temperature and relative humidity). The synthesis of these relatively well-defined graft structures involves three reaction steps, including the preparation of PVDF copolymers containing a few mol% of chlorotrifluoroethylene (CTFE) units, the ATRP graft-from reaction to incorporate several polystyrene side chains, and the subsequent sulfonation reaction on the PS side chains. The PVDF-g-SPS graft copolymer with a combination of a high PVDF backbone molecular weight (Mn >300 000 g/mol), very low SPS graft density (0.3 mol%), and high graft length (SPS content >30 mol%) presents an interesting material for the proton exchange membrane (PEM). This graft copolymer self-assembles into a microphase-separated morphology with randomly oriented long-range lamella/cylinder ionic channels (with small widths) that are imbedded in the hydrophobic semicrystalline PVDF matrix. This graft copolymer morphology offers a high ion exchange capacity (IEC = 2.75 mmol/g) and resistance to excessive water swelling, which yields notably higher proton conductivity than Nafion under 30-120 °C and high humidity conditions.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.