Mesoporous films prepared from synthesized TiO2 nanoparticles and their application in dye-sensitized solar cells (DSSCs)
By Tasi?, Nikola; Stanojevi?, Zorica Marinkovi?; Brankovi?, Zorica; La?njevac, Uro
Published in Electrochimica Acta
NULL
2016
Abstract
Abstract In this paper, we propose a novel method for preparation of high surface area titania nanoparticles, and investigate their photovoltaic performance in dye sensitized solar cells (DSSCs). The precursor compound titanium(IV)-isopropoxide is hydrolyzed in the presence of nonionic surfactant (Triton X100) and ethylenediaminetetraacetic acid sodium salt (EDTA-Na2) and thermally transformed into gel. The gel is autoclaved, resulting in submicronic micelles which are further processed into mesoporous films. The films are deposited from paste, composed of ultrasonically broken micelles and the organic ingredients. The crack-free film structures, composed of sub-25 nm pure anatase particles are observed using the appropriate instrumental techniques: scanning electron microscopy (SEM), field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), X-ray diffractometry (XRD), UV-VIS-NIR spectroscopy. The large surface area of 158 m2 g?1 and mesoporosity are confirmed using the data obtained from the nitrogen adsorption-desorption isotherm. The photovoltaic performance of the operating N719-sensitized solar devices are tested using electrochemical impedance spectroscopy (EIS), open-circuit voltage decay (OCVD) and by recording current density-voltage (J-V) curves. The cell exhibits promising photocurrent density up to 11.7 mA cm?2, and the photo-to-electric power efficiency of 5.22%, for cell area of 0.24 cm2, under 100 mW cm?2 halogen light source.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.