Solid particle erosion–corrosion behaviour of a novel HVOF nickel aluminium bronze coating for marine applications—correlation between mass loss and electrochemical measurements
By Tan, K.S.; Wharton, J.A. & Wood, R.J.K.
Published in Wear
NULL
2005
Abstract
This paper investigates the solid particle erosion–corrosion performance of an experimental high velocity oxy-fuel (HVOF) sprayed nickel–aluminium bronze (NAB) coating using conventional gravimetric techniques as well as in situ electrochemical analysis. The coating consists of HVOF powders from three alloys: stainless steel alloy, nickel-based alloy and aluminium bronze alloy. It is a candidate coating for marine applications as a cost effective replacement of existing castings and to improve component life. The coating was subjected to pure erosion, flow corrosion and erosion–corrosion tests. A jet impingement slurry erosion rig was used to carry out the experiments; the effects of jet velocity were investigated. By gravimetric analysis the degree of synergy was evaluated and a constant was revealed which described to what extent the presence of corrosion products/films reduces the erosivity and promotes negative synergy. Likewise, standard deviations of electrochemical current measurements are shown to reveal the presence of protective film formation under flow corrosion and film breakdown under erosion–corrosion conditions. Separation of the erosion-enhanced corrosion component revealed that at high erodent kinetic energies, erosion-enhanced corrosion dominates and generates a positive synergy. At lower energies, this coating system forms a protective film which reduces the contact conditions on impingement and a negative synergy results. Overall, correlations between the mass loss and electrochemical measurements have been established and were used to identify and quantify synergy.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.