Non-uniform aging of cycled commercial LiFePO₄//graphite cylindrical cells revealed by post-mortem analysis
By Klett, Matilda; Eriksson, Rickard; Groot, Jens; Svens, Pontus; Högström, Katarzyna Ciosek; Lindström, Rakel Wreland; Berg, Helena; Gustafson, Torbjörn; Lindbergh, Göran & Edström, Kristina
Published in Journal of Power Sources
NULL
2014
Abstract
Aging of power-optimized commercial 2.3 Ah cylindrical LiFePO₄//graphite cells to be used in hybrid electric vehicle is investigated and compared for three different aging procedures; (i) using a simulated hybrid electric vehicle cycle within a narrow SOC-range, (ii) using a constant-current cycle over a SOC-range, and (iii) stored during three years at 22 °C. Postmortem analysis of the cells is performed after full-cell electrochemical characterization and discharge. EIS and capacity measurements are made on different parts of the disassembled cells. Material characterization includes SEM, EDX, HAXPES/XPS and XRD. The most remarkable result is that both cycled cells displayed highly uneven aging primarily of the graphite electrodes, showing large differences between the central parts of the jellyroll compared to the outer parts. The aging variations are identified as differences in capacity and impedance of the graphite electrode, associated with different SEI characteristics. Loss of cyclable lithium is mirrored by a varying degree of lithiation in the positive electrode and electrode slippage. The spatial variation in negative electrode degradation and utilization observed is most likely connected to gradients in temperature and pressure, that can give rise to current density and potential distributions within the jellyroll during cycling.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.