Development of a galvanic sensor system for detecting the corrosion damage of the steel embedded in concrete structure: Part 2. Laboratory electrochemical testing of sensors in concrete
By Park, Zin-Taek; Choi, Yoon-Seok; Kim, Jung-Gu & Chung, Lan
Published in Cement and Concrete Research
NULL
2005
Abstract
The correlation between sensor output and the corrosion rate of steel bar was confirmed in concrete environment. Open-circuit potential, linear polarization resistance (LPR) measurement and electrochemical impedance spectroscopy (EIS) were used to evaluate the corrosion behavior of steel bar embedded in concrete. Also, galvanic current measurements of designed sensors were conducted to obtain the charge of sensor embedded in concrete. In this study, the results of corrosion behavior of reinforcing steel showed a consistence among the data obtained by open-circuit potential monitoring, LPR and EIS measurements. Steel/copper sensor showed a good correlation in concrete environment between sensor output and corrosion rate of steel bar. However, there was no relationship between steel/stainless steel sensor output and corrosion rate of steel bar due to the low galvanic current output. Through the relationship between the steel/copper sensor output and the corrosion rate of reinforcing steel, the real corrosion damage of the reinforcing steel can be detected. Consequently, this confirms that the galvanic sensor system is a good method for detection of corrosion in reinforced concrete.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.