Synthesis and characterization of conducting polymers containing polypeptide and ferrocene side chains as ethanol biosensors
By Kesik, Melis; Akbulut, Huseyin; Soylemez, Saniye; Cevher, Sevki Can; H[i without dot]zalan, Gonul; Arslan Udum, Yasemin; Endo, Takeshi; Yamada, Shuhei; C[i without dot]rpan, Ali; Yagc[i without dot], Yusuf & Toppare, Levent
Published in Polym. Chem.
The Royal Society of Chemistry
2014
Abstract
A novel approach for the fabrication of a biosensor from a conducting polymer bearing polypeptide segments and ferrocene moieties is reported. The approach involves the electrochemical copolymerization of the electroactive polypeptide macromonomer and independently prepared ferrocene imidazole derivative of dithiophene, on the electrode surface. The polypeptide macromonomer was synthesized by the simultaneous formation of N-carboxyanhydride (NCA) and ring opening polymerization of N-Boc-l-lysine ([small alpha]-amino acid of the corresponding NCA) using an amino functional bis-EDOT derivative (BEDOA-6) as an initiator. Alcohol oxidase was then covalently immobilized onto the copolymer coated electrode using glutaraldehyde as the crosslinking agent. The intermediates and final conducting copolymer before and after enzyme immobilization were fully characterized by FT-IR, 1H-NMR, GPC, cyclic voltammetry, SEM and EIS analyses. The newly designed biosensor which combined the advantages of each component was tested as an ethanol sensing system offering fast response time (9 s), wide linear range (0.17 mM and 4.25 mM) and low detection limit (0.28 mM) with a high sensitivity (12.52 [small mu ]A mM-1 cm-2). Kinetic parameters KappM and Imax were 2.67 mM and 2.98 [small mu ]A, respectively. The capability of the biosensor in determining ethanol content in alcoholic beverages was also demonstrated.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.