A novel carboxymethylcellulose–gelatin–titanium dioxide–superoxide dismutase biosensor; electrochemical properties of carboxymethylcellulose–gelatin–titanium dioxide–superoxide dismutase
By Emregul, Emel; Kocabay, Ozge; Derkus, Burak; Yumak, Tugrul; Emregul, Kaan Cebesoy; Sinag, Ali & Polat, Kamran
Published in Bioelectrochemistry
NULL
2013
Abstract
A novel highly sensitive electrochemical carboxymethylcellulose–gelatin–TiO2–superoxide dismutase biosensor for the determination of O2•- was developed. The biosensor exhibits high analytical performance with a wide linear range (1.5 nM to 2 mM), low detection limit (1.5 nM), high sensitivity and low response time (1.8 s). The electron transfer of superoxide dismutase was first accomplished at the carboxymethylcellulose–gelatin–Pt and carboxymethylcellulose–gelatin–TiO2–Pt surface. The electron transfer between superoxide dismutase and the carboxymethylcellulose–gelatin–Pt wihout Fe(CN)64 -/3 - and carboxymethylcellulose–gelatin–Pt, carboxymethylcellulose–gelatin–TiO2–Pt with Fe(CN)64 -/3 - is quasireversible with a formal potential of 200 mV, 207 mV, and 200 mV vs Ag|AgCl respectively. The anodic (ksa) and cathodic (ksc) electron transfer rate constants and the anodic (αa) and cathodic (αc) transfer coefficients were evaluated: ksa = 6.15 s- 1, αa = 0.79, and ksc = 1.48 s- 1 αc = 0.19 for carboxymethylcellulose–superoxide dismutase without Fe(CN)64 -/3 -, ksa = 6.77 s- 1, αa = 0.87, and ksc = 1 s- 1 αc = 0.13 for carboxymethylcellulose–superoxide dismutase with Fe(CN)64 -/3 -, ksa = 6.85 s- 1, αa = 0.88, and ksc = 0.76 s- 1 αc = 0.1 carboxymethylcellulose–gelatin–TiO2–superoxide dismutase. The electron transfer rate between superoxide dismutase and the Pt electrode is remarkably enhanced due to immobilizing superoxide dismutase in carboxymethylcellulose–gelatin and TiO2 nanoparticles tend to act like nanoscale electrodes.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.