Visible light active C-doped titanate nanotubes prepared via alkaline hydrothermal treatment of C-doped nanoparticulate TiO2: Photo-electrochemical and photocatalytic properties
By Neville, Elaine M.; MacElroy, J.M. Don; Thampi, K. Ravindranathan & Sullivan, James A.
Published in Journal of Photochemistry and Photobiology A: Chemistry
NULL
2013
Abstract
Carbon-doped titanate nanotubes (C-TNT) were formed via alkaline hydrothermal treatment of a TiO2 nanoparticulate material pre-doped with carbon. Attempts to form C and W co-doped titanate nanotubes using analogous C and W co-doped nanoparticulate materials were unsuccessful. Physical characterisations, such as X-ray diffraction, N2 physisorption and transmission electron microscopy, confirmed the formation of titanate nanotubes ∼7 nm in diameter and hundreds of nm in length with increased surface areas relative to the nanoparticulate precursors. X-ray photoelectron spectroscopy confirmed the retention of substitutional carbon dopant and the exclusion of tungsten dopant from the doped TNT materials. Converting doped (or undoped TiO2) into C-TNT (or TNT) slightly increases the material's bandgap but the C-TNT material (in contrast to TNT and undoped TiO2) absorbs into the visible region of the spectrum. C-doped and un-doped titanate nanotube materials were more active in promoting the photo degradation of 4-chlorophenol under visible light than their analogous nanoparticulate precursors. C-TNT was the most photocatalytically active material tested. However, photocurrent response measurements showed C-TNT to be less effective at generating current following irradiation than both its nanoparticulate analogue and nanoparticulate P25 when screen printed onto electrode surfaces. We ascribe this to non-optimal alignment of the TNTs on the electrode surface.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.