Electrochemical NOx reduction on an LSM/CGO symmetric cell modified by NOx adsorbents
By Shao, Jing & Hansen, Kent Kammer
Published in J. Mater. Chem. A
The Royal Society of Chemistry
2013
Abstract
This study investigated the effect of modifying a (La0.85Sr0.15)0.99MnO3 (LSM)/Ce0.9Gd0.1O1.95 (CGO) symmetric cell by NOx adsorbents on the electrochemical reduction of NOx under O2-rich conditions. The modification was based on a full ceramic cell structure without any noble metals. Three cells were prepared and tested: a blank cell, a cell impregnated with BaO, and a cell coated with a BaO/Pt/Al2O3 layer. The electrochemical reduction of NOx on the three cells was studied by conversion measurement, degradation testing, and microstructure characterization. The modification, either by impregnating the BaO into the electrode or by coating the Ba/Pt/Al2O3 layer on the surface of the electrode, significantly increased the activity and selectivity of the NOx reduction on the LSM/CGO symmetric cell by enhancing the adsorption and storage of the NOx species or providing reaction sites for direct nitrate reduction. The cell with the BaO/Pt/Al2O3 layer exhibited a preferable performance at low temperatures (350 and 400 [degree]C) and low voltages (1.5 to 2 V) due to the NO oxidation ability of the Pt catalyst, although its performance was relatively poor at elevated temperatures and voltages due to the impedance of the diffusion of NOx to the reaction sites by the adsorption layer. For lowering the operation temperature and minimizing the power consumption, adding an adsorption layer was shown to be the optimum approach for modifying the electrochemical cell by NOx adsorbents. The square wave (SV) polarization can balance the trapping and reduction rates of NOx species on the electrochemical cells to further improve the NOx reduction relative to the direct current (DC) polarization.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.