Heck Coupling of Olefins to Mixed Methyl/Thienyl Monolayers on Si(111) Surfaces
By O'Leary, Leslie E.; Rose, Michael J.; Ding, Tina X.; Johansson, Erik; Brunschwig, Bruce S. & Lewis, Nathan S.
Published in Journal of the American Chemical Society
NULL
2013
Abstract
The Heck reaction has been used to couple olefins to a Si(111) surface that was functionalized with a mixed monolayer comprised of methyl and thienyl groups. The coupling method maintained a conjugated linkage between the surface and the olefinic surface functionality, to allow for facile charge transfer from the silicon surface. While a Si(111) surface terminated only with thienyl groups displayed a surface recombination velocity, S, of 670 ± 190 cm s -1, the mixed CH3/SC4H3 -Si(111) surfaces with a coverage of θSC4H3 = 0.15 ± 0.02 displayed a substantially lower value of S = 27 ± 9 cm s -1. Accordingly, CH3/SC4H3 -Si(111) surfaces were brominated with N-bromosuccinimide, to produce mixed CH3/SC4H2Br -Si(111) surfaces with coverages of θBr -Si < 0.05. The resulting aryl halide surfaces were activated using [Pd(PPh3)4] as a catalyst. After activation, Pd(II) was selectively coordinated by oxidative addition to the surface-bound aryl halide. The olefinic substrates 4-fluorostyrene, vinylferrocene, and protoporphyrin IX dimethyl ester were then coupled (in dimethylformamide at 100 °C) to the Pd-containing functionalized Si surfaces. The porphyrin-modified surface was then metalated with Co, Cu, or Zn. The vinylferrocene-modified Si(111) surface showed a linear dependence of the peak current on scan rate in cyclic voltammetry, indicating that facile electron transfer had been maintained and providing evidence of a robust linkage between the Si surface and the tethered ferrocene. The final Heck-coupled surface exhibited S = 70 cm s -1, indicating that high-quality surfaces could be produced by this multistep synthetic approach for tethering small molecules to silicon photoelectrodes.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.