Lithium ion-inserted TiO2 nanotube array photoelectrocatalysts
By Kang, Unseock & Park, Hyunwoong
Published in Applied Catalysis B: Environmental
NULL
2013
Abstract
A quick electrochemical Li ion insertion into TiO2 nanotube arrays (TNTs) markedly enhances the photoelectrochemical and photoelectrocatalytic performance. Potential pulses (-1.0 ∼ -1.7 VSCE for 1–11 s in 1 M LiClO4) to pre-annealed TNTs effectively insert Li ions (pre-annealed Li-TNTs) into the mouth/wall and bottom TiO2 depending on the insertion condition. Pre-annealed Li-TNTs prepared under an optimal Li ion insertion condition (-1.4 VSCE for 3 s) exhibit ∼70%-enhanced photocurrent generation, ∼2.5 fold-higher incident photon-to-current efficiency, and an improved photoelectrocatalytic activity for the degradation of phenolic compounds in 1 M KOH electrolyte. A change in photoluminescence (PL) emission spectra and decrease in charge transfer resistance by Li ion insertion suggest that the inserted Li ions play a role in inhibiting charge recombination by compensating for the photogenerated Ti3+ charges (Li+-Ti3+-OH). However, as KOH concentration is diluted such enhanced Li+ effects gradually vanish primarily due to liberation of reversibly inserted Li ions. To insert Li ions irreversibly, the potential pulses were applied to non-annealed TNTs followed by annealing (post-annealed Li-TNTs). Comparison between pre-annealed and post-annealed Li-TNTs in circum-neutral pH (0.1 M Na2SO4 at pH ∼6) indicates that the former exhibits a similar performance to bare TNTs (absence of Li ion effect), whereas the latter shows a superior performance with ca. 2.5-fold higher photoelectrochemical and photoelectrocatalytic activities. Detailed surface analyses (XPS, XRD, PL, SEM, ICP-MS, etc.) and Li+-induced reaction mechanism were discussed.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.