Microstructure and corrosion resistance of enamel coatings applied to smooth reinforcing steel
By Tang, Fujian; Chen, Genda; Volz, Jeffery S.; Brow, Richard K. & Koenigstein, Mike
Published in Construction and Building Materials
NULL
2012
Abstract
Corrosion behavior of enamel-coated reinforcing steel bars in 3.5 wt.% NaCl solution is evaluated by open-circuit potential, electrochemical impedance spectroscopy (EIS) and potentiodynamic polarization testing. Three types of enamel coating are investigated: a pure enamel coating, a mixed enamel coating that consists of 50% pure enamel and 50% calcium silicate by weight, and a double enamel coating that has an inner pure enamel layer and an outer 50/50 enamel layer. The coatings are characterized with X-ray diffraction (XRD), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS) techniques. SEM images reveal that all three enamel coatings have a porous structure. The pores in the pure and double enamel are disconnected, while those in the mixed enamel are interconnected. Electrochemical tests demonstrate that both pure and double enamel coatings can significantly improve corrosion resistance, while the mixed enamel coating offers very little protection.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.