In situ study of coatings using embedded electrodes for ENM measurements
By Chidambaram, Devicharan; Clayton, Clive R. & Dorfman, Mitchell R.
Published in Progress in Organic Coatings
NULL
2003
Abstract
After preliminary studies attempting to use electrochemical impedance spectroscopy (EIS) as a method for in situ measurement of the corrosion protective properties of coatings failed, the use of electrochemical noise methods (ENMs) was examined for this purpose. It has been found that a modified version of the electrode configuration that is most commonly used for ENM in the study of coatings involving embedded wires in the coating film allows one to perform in situ measurements of the electrochemical properties of the film. These continuous measurements of electrochemical properties of coatings in exposure are the very first of this type of measurement ever accomplished. The results of our preliminary studies from ENM in an embedded two-electrode configuration are presented. These studies examined the use of embedded electrodes in coatings on exposure in a cyclic salt fog test chamber (Prohesion™ cycle). The test panels under examination undergo exposures that involve changes in temperature, humidity and electrolyte spraying, and are thus a good emulation of exterior exposure. Results are presented for several types of films along with in situ temperature measurements on the test panels under study. An analysis of this data is given which indicates that coating film noise resistance, Rn, decreases as moisture penetrates the film during the “spray cycle�, then rises again during the “dry cycle� in a manner that lags the temperature cycle, while the “localization index� of corrosion as defined by Eden goes through a maximum at the end of the “dry cycle�. This would seem to indicate the internal increase in electrolyte concentration in the film that occurs during drying is one of the key drivers of the transition from low rate general corrosion to the onset of localized corrosion. Implications of the results and the possible uses of the sensing system are also discussed.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.