Corrosion-wear evaluation of a UHMWPE/Co–Cr couple in sliding contact under relatively low contact stress in physiological saline solution
By Figueiredo-Pina, Célio Gabriel; Neves, Armanda Agostinho Matos & das Neves, Bruno Miguel Bandarra
Published in Wear
NULL
2011
Abstract
Several tribocorrosion studies have been carried out using metal on metal (MOM) and ceramic on metal (COM) materials combinations in order to understand the behavior of these materials when applied in human joint replacement. However, there are few studies in this area focused on processes of tribocorrosion occurring at the interface between a metal and a polymer. Thus, the aim of this study was to evaluate the tribocorrosion behavior between cobalt chromium and ultra-high molecular weight polyethylene (UHMWPE) under relatively low contact stress. Reciprocating corrosion–wear tests were performed using plates of cobalt-chromium alloy and UHMWPE pins under a load of 1.84 N (giving a contact stress of 39 kPa) in a 0.9% NaCl solution, during 1 h. The tribocorrosion tests were performed at open circuit potential (OCP), during anodic polarization scans and at potentiostatic conditions of -150, -100, 200 and -800 mV vs. SCE. The electrochemical wear rates were estimated using the Faraday equation. The OCP results showed a dramatically decrease of potential during the mechanical contact, while the anodic polarization scans revealed an increase of current during mechanical contact. Finally, potentiostatic tests carried out at -150, -100 and 200 mV vs. SCE displayed an increase of anodic current during mechanical contact, while the tests carried out under -800 mV vs. SCE showed an increase of the cathodic current during mechanical contact. Thus, this set of results provides evidences of tribocorrosion when the mechanical contact was applied to the system, even though the applied stress was relatively low.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.