Corrosion of CoCr and NiCr dental alloys alloyed with palladium
By Sarantopoulos, Demetrios M.; Beck, Kelly A.; Holsen, Robert & Berzins, David W.
Published in The Journal of Prosthetic Dentistry
NULL
2011
Abstract
Statement of problem A new subclass of casting alloy composition involving the addition of palladium (25 wt%) to traditional base metal alloys, thereby raising their classification to that of a noble alloy, has been recently introduced. Little is known about this class of casting alloy, particularly its corrosion properties, which influence its biocompatibility and esthetics. Purpose The purpose of this study was to evaluate the corrosion properties of 2 new CoPdCr and one new NiPdCr alloy and compare them to traditional CoCr and NiCr alloys. Material and Methods The casting alloys investigated were: CoPdCr-A (NobleCrown NF), CoPdCr-I (Callisto CP+), NiPdCr (Noble Crown), CoCr (Argeloy N.P. Special), and NiCr (Argeloy N.P. Star). Cylindrical (4.8-mm diameter) as-cast and oxidized specimens were assessed electrochemically in phosphate-buffered saline at 24°C (n=8 and n=6, respectively). The open circuit potential (OCP) was monitored for 20 hours, followed by linear polarization and cyclic polarization tests. A generalized linear mixed model was used to determine whether differences existed between alloys and to examine the effect of oxidation (α=.05). Representative alloy surfaces were scanned and examined with light microscopy. Results The palladium-containing alloys possessed a significantly greater OCP (P<.001); however, their polarization resistance was less and the corrosion current density was significantly greater (P<.05) than their traditional CoCr and NiCr alloy counterparts. Additionally, a greater incidence of pitting was observed in the palladium-containing alloys. Some differences were noted within alloys between the as-cast and oxidized conditions, but a major trend was not observed. Conclusions Overall, the inclusion of palladium in CoCr and NiCr alloys had deleterious effects on electrochemical corrosion properties.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.