Simultaneous determination of paracetamol and neurotransmitters in biological fluids using a carbon paste sensor modified with gold nanoparticles
By Atta, Nada F.; Galal, Ahmed; Abu-Attia, Fekria M. & Azab, Shereen M.
Published in J. Mater. Chem.
The Royal Society of Chemistry
2011
Abstract
A promising electrochemical sensor was developed by electrodeposition of gold nanoparticles on a carbon paste (CP) electrode. This sensor electrode (CPE-Aunano) was used to determine paracetamol (ACOP) and some neurotransmitters, such as dopamine (DA), epinephrine (EP), norepinephrine (NP), levodopa (L-DOPA) and serotonin (5-HT). Cyclic and differential pulse voltammetry studies indicated that the oxidation of paracetamol at the electrode surface proceeded through a two electron reversible step and was fundamentally controlled by adsorption. Further modification of the sensor by mixing the CPE-Aunano with Nafion[registered sign] showed good sensitivity and effectively resolved the overlapping anodic peaks of these neurotransmitters (NTs) with ACOP. Also, the interfering effect of physiologically common interferences, namely ascorbic acid (AA) and uric acid (UA), on the current response of paracetamol has been studied. Nafion[registered sign] proved to increase the sensitivity of the current signal of the sensor for the oxidation of the compounds studied. Paracetamol gave a well defined oxidation peak at 430 mV in pH 7.4, which was used to quantitate the drug in the two ranges of 50 nM-50 [small mu ]M and 90-270 [small mu ]M with a detection limit of 7.7 nM and 28 nM, respectively. The procedure was successfully validated for the assay of paracetamol in pharmaceutical formulations. The applicability of the developed method to determine the drug in human urine samples is also illustrated.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.