Faster oxygen atom transfer catalysis with a tungsten dioxo complex than with its molybdenum analog
By Arumuganathan, T.; Mayilmurugan, Ramasamy; Volpe, Manuel & Mosch-Zanetti, Nadia C.
Published in Dalton Trans.
The Royal Society of Chemistry
2011
Abstract
The synthesis and characterization of a series of molybdenum ([MoO2Cl(Ln)]; L1 (1), L2 (3)) and tungsten ([WO2Cl(Ln)]; L1 (2), L2 (4)) dioxo complexes (L1 = 1-methyl-4-(2-hydroxybenzyl)-1, 4-diazepane and L2 = 1-methyl-4-(2-hydroxy-3, 5-di-tert-butylbenzyl)-1, 4-diazepane) of tridentate aminomonophenolate ligands HL1 and HL2 are reported. The ligands were obtained by reductive amination of 1-methyl-1, 4-diazepane with the corresponding aldehyde. Complexes 3 and 4 were obtained by the reaction of [MO2Cl2(dme)n] (M = Mo, n = 0; W, n = 1) with the corresponding ligand in presence of a base, whereas for the preparation of 1 and 2 the ligands were deprotonated by KH prior to the addition to the metal. They were characterized by NMR and IR spectroscopy, by cyclic voltammetry, mass spectrometry, elemental analysis and by single-crystal X-ray diffraction analysis. Solid-state structures of the molybdenum and tungsten cis-dioxo complexes reveal hexa-coordinate metal centers surrounded by two oxo groups, a chloride ligand and by the tridentate monophenolate ligand which coordinates meridionally through its [ONN] donor set. In the series of compounds 1-4, complexes 3 and 4 have been used as catalysts for the oxygen atom transfer reaction between dimethyl sulfoxide (DMSO) and trimethyl phosphine (PMe3). Surprisingly, faster oxygen atom transfer (OAT) reactivity has been observed for the tungsten complex [WO2Cl(L2)] (4) in comparison to its molybdenum analog [MoO2Cl(L2)] (3) at room temperature. The kinetic results are discussed and compared in terms of their reactivity.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.