Abstract
The performance of a surface-applied migrating corrosion inhibitor (MCI) based on an alkylaminoalcohol was evaluated on concrete specimens containing reinforcing steel bar (rebar) segments. Two water/cement ratios (w/c's), various chloride contents and two exposure conditions were investigated. The inhibiting efficiency was followed over a period of 1000 days by means of parameters such as corrosion potential, corrosion current and electrical resistance. Results show that when concrete is exposed to the marine environment, the inhibitor is able to reduce the corrosion rate (CR) only when the initial chloride content is below 0.16 wt.% relative to cement content. Efficiency increases as the w/c increases. There is no beneficial effect when the initial chloride content is greater than 0.43%. When concrete is immersed in a saline solution, no beneficial effect associated to the use of the inhibitor could be appreciated, regardless of w/c or initial chloride content in concrete.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.