Synthesis, enhanced spectroscopic characterization and electrochemical grafting of N-(4-aminophenyl)aza-18-crown-6: Application of DEPT, HETCOR, HMBC-NMR and X-ray photoelectron spectroscopy
By Deveci, Pervin; Taner, Bilge;Üstündağ, Zafer; Özcan, Emine; Solak, Ali Osman & Kılıç, Zeynel
Published in Journal of Molecular Structure
NULL
2010
Abstract
This work describes the synthesis, characterization and electrochemical grafting of N-(4-aminophenyl)aza-18-crown-6 (4APA18C6). The key step in the synthesis is the reaction of N-phenylaza-18-crown-6 (PA18C6) with sodium nitrite. The compound, N-(4-nitrosophenyl)aza-18-crown-6 (NOPA18C6) could not be isolated purely from the reaction mixture, but a reduction of the residue with SnCl2 gave the desired azacrown ether, N-(4-aminophenyl)aza-18-crown-6 (4APA18C6).To confirm its proposed structure detailed characterization techniques such as elemental analysis, FT-IR, 1H NMR, 13C NMR, DEPT, HETCOR, HMBC and ESI mass-spectrometry were used. Due to the importance of azacrown compounds in the field of analytical chemistry, in the derivatization of dyes, chemical sensors and ionic extraction, as molecular receptors, grafting of 4APA18C6 on the glassy carbon (GC) surface has been investigated by amine oxidation to gain new insight into the modification area. The oxidation mechanism has been established, and the results are in accordance with the attachment of amines to a glassy carbon surface by cyclic voltammetry. The modification of 4APA18C6 molecules onto the glassy carbon surface was verified by cyclic voltammetry (CV), X-ray photoelectron spectroscopy (XPS) reflection–absorption infrared spectroscopy (RAIRS) and ellipsometry. The film on the GC surface was formed according to the layer-by-layer mechanism and the ellipsometric thickness was obtained around 11.5 ± 1.1 nm.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.