An automated system for measuring tip impedance and among-electrode shunting in high-electrode count microelectrode arrays
By Gunalan, Kabilar; Warren, David J.; Perry, Justin D.; Normann, Richard A. & Clark, Gregory A.
Published in Journal of Neuroscience Methods
NULL
2009
Abstract
The development and effective use of robust high-electrode-count microelectrode arrays for neuronal recording and stimulation depends on effective monitoring of electrode impedances and how these change over time. In multielectrode arrays, conventional electrode impedance measurements may be confounded by possible shunting of signals among electrodes. Additionally, most present methods to monitor impedances in high-electrode-count arrays are labor intensive, requiring manual testing of one individual electrode at a time. We have developed a system capable of automatically measuring the impedances of each microelectrode on a 100-microelectrode array with a 1-kHz, 10-mV sine wave. Through switching logic, two impedance values are measured for each electrode in an array: (1) the unshunted impedance (presumably representing the actual tip impedance); and (2) the shunted impedance. These two measurements are used to calculate the net impedance of leakage/shunting pathways from the test electrode through all the other electrodes in the array. The system measures impedances in the range of 300 Ω–10 MΩ. The system was validated with simple resistor ladder networks, and measurements of the modeled electrode tip impedances were within 2% of independently measured values. Additionally, the system reliably indicated the relative values of the net shunting impedances, although high values were systematically underestimated. The automated device was capable of measuring electrode tip and net shunting impedance values for a 100-microelectrode array in 5 min. These rapid and repeatable measurements allow for the quantitative assessment of high-electrode-count arrays over time.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.