Preconcentration mechanism of trivalent lanthanum on eQCM electrodes in the presence of α-hydroxy isobutyric acid
By Medina, Adan Schafer; Wall, Nathalie A.; Ivory, Cornelius F.; Clark, Sue B.; Beyenal, Haluk
Published in Journal of Electroanalytical Chemistry
2020
Abstract
Electroprecipitation can be used to preconcentrate lanthanum on carbon electrode surfaces. The use of complexing ligands is expected to improve the electroprecipitation of lanthanum by protecting La ions in solution from the alkaline region near the electrode surface. However, the electroprecipitation mechanism of La in the presence of a complexing ligand is not known. The goal of this work is to 1) determine the effect of the complexing ligand, α-hydroxy isobutyric acid (HIBA), on the electroprecipitation of La onto the gold electrodes, and 2) identify the changes in the mechanism of accumulation when preconcentrating in the presence of HIBA. We used an electrochemical quartz crystal microbalance (eQCM) and needle type pH microelectrodes to determine pH near the electrode surface in combination with cyclic voltammetry to understand the electroprecipitation mechanism. We used the bi-dentate ligand HIBA as a ligand and found that lanthanum electroprecipitation is hindered in the presence of HIBA. The presence of HIBA also delayed the onset of film formation during a cyclic voltammetric experiment by 100 mV compared to experiments performed without HIBA. The shift in onset potential is attributed to the buffering action of HIBA (pKa = 3.7) since the shift is not present in subsequent scans. The precipitated film was characterized by scanning electron microscopy, X-ray photoelectron spectrometry, and Auger nanoprobe spectrometry. While we found that La(OH)3 was the predominant chemical state of the film on electrodes in the absence of HIBA, La2O3 was found for films created in the presence of HIBA. Our finding demonstrates that La(OH)3 can be electrodeposited at room temperature.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.