Photocatalysis of Dye-Sensitized TiO2 Nanoparticles with Thin Overcoat of Al2O3: Enhanced Activity for H2 Production and Dechlorination of CCl4
By Kim, Wooyul; Tachikawa, Takashi; Majima, Tetsuro & Choi, Wonyong
Published in The Journal of Physical Chemistry C
NULL
2009
Abstract
Dye-sensitized TiO2 nanoparticles that were loaded simultaneously with Pt and Al2O3 overlayer (Al2O3/TiO2/Pt) were synthesized and investigated for photocatalytic activity under visible light. Introducing a thin Al2O3 overlayer (∼1 nm thick) on dye-sensitized TiO2 markedly enhanced the visible light activities for the production of hydrogen (in the presence of EDTA as an electron donor) and the dechlorination of CCl4. The Al2O3/TiO2/Pt powder was characterized by HRTEM, EDX, and XPS. In agreement with the photocatalytic activity data, the photocurrent collected via electron shuttles on a Pt electrode immersed in an aqueous photocatalyst suspension under visible light was also enhanced in the presence of an Al2O3 overlayer, which indicates an enhanced interfacial electron transfer despite the presence of an insulating surface layer. The initial H2 and chloride generation rate increased from 0.4 and 5 μM min-1 on TiO2/Pt to 0.9 and 7.5 μM min-1 on Al2O3/TiO2/Pt, respectively. The visible light activity of the sensitized photocatalytic reactions highly depended on the thickness of the alumina layer and was optimized at a low level of Al loading (Al/Ti atom ratio ∼ 0.01), above which the activity was markedly reduced with thickening of the layer. It is suggested that the alumina layer retards the charge recombination between the electron injected from the excited dye and the oxidized dye. The slower charge recombination in the presence of an alumina overlayer was confirmed by time-resolved diffuse reflectance (TDR) spectroscopy.
Microsoft is Ending Support for Windows 7
Microsoft will discontinue support for Windows 7 on January 14, 2020 which means Gamry will also be discontinuing support for Windows 7. If you are upgrading to Windows 10, like many companies and institutions, you need to be running Version 7 of our s oftware . Please note that only USB and Ethernet-based instruments can run in Version 7. Eligible users can download the latest version of our software through our online Client Portal .
If you haven't already registered your instrument, you can do so through the Client Portal .
Please email Technical Support if you have any questions regarding this transition. Please be sure to include your instrument model and serial number when contacting us.